Cancer Research and Treatment ; : 1120-1129, 2016.
Article in English | WPRIM | ID: wpr-68882

ABSTRACT

PURPOSE: This study was designed to characterize the pharmacokinetic profile and to assess bioequivalence of the sponsor's test formulation (imatinib mesylate 400 mg tablets) with an innovator product (Gleevec 400 mg tablets, Novartis Pharmaceuticals) under fed conditions, in adult patients of Philadelphia chromosome positive chronic myeloid leukemia (Ph+ CML) stabilized on imatinib mesylate 400 mg. In addition, the aim of this study was to monitor the safety profile of investigational medicinal products (IMPs). MATERIALS AND METHODS: A multicenter, randomized, open label, two-period, crossover, single dose bioequivalence study was designed for conduct under fed conditions in 42 adult Ph+ CML patients already stabilized on imatinib 400 mg tablets. Pharmacokinetic parameters Tmax, Cmax, and AUC0-24 were calculated using a non-compartmental model on validated WinNonlin software. Validated SAS software was used for statistical evaluation of data. The safety profile of investigational products was monitored during the course of study by applying a clinical process for recording observed untoward effects postadministration of investigational products. RESULTS: The 90% confidence intervals for the test/reference mean ratios of the ln-transformed PK variables Cmax (99.0%) and AUC0-24 (99.2%) were within an acceptable range of 80%-125%, as per bioequivalence assumptions. Both formulations were well tolerated after oral administration of IMPs. CONCLUSION: The test product was found to be bioequivalent and safe, and thus can be used interchangeably in clinical practice.


Subject(s)
Adult , Humans , Administration, Oral , Imatinib Mesylate , Leukemia , Leukemia, Myelogenous, Chronic, BCR-ABL Positive , Mesylates , Pharmacokinetics , Philadelphia Chromosome , Tablets , Therapeutic Equivalency
2.
Journal of Pharmaceutical Analysis ; (6): 190-199, 2015.
Article in Chinese | WPRIM | ID: wpr-467109

ABSTRACT

An analytical method based on solid phase extraction was developed and validated for analysis of adefovir in human plasma. Adefovir-d4 was used as an internal standard and Synergi MAX RP80A (150 mm × 4.6 mm, 4μm) column provided the desired chromatographic separation of compounds followed by detection with mass spectrometry. The method used simple isocratic chromato-graphic condition and mass spectrometric detection in the positive ionization mode. The calibration curves were linear over the range of 0.50–42.47 ng/mL with the lower limit of quantitation validated at 0.50 ng/mL. Matrix effect was assessed by post-column infusion experiment to monitor phospholipids and post-extraction addition experiment was performed. The degree of matrix effect for adefovir was determined as 7.5%and ion-enhancement in five different lots of human plasma was 7.1%and had no impact on study samples analysis with 4.5 min run time. The intra- and inter-day precision values were within 7.7% and 7.8%, respectively, for adefovir at the lower limit of quantification level. Validated bioanalytical method was successfully applied to clinical sample analysis.

3.
Pakistan Journal of Pharmaceutical Sciences. 2013; 26 (3): 465-472
in English | IMEMR | ID: emr-142605

ABSTRACT

In this study a rapid, simple and sensitive assay to quantify clozapine in human plasma by using reverse phase high performance liquid chromatographic method has been developed. Clozapine was extracted from human plasma using a mixture of chloroform: n-hexane 50:50 employing liquid- liquid extraction method. The calibration curve was found to be linear in the concentration range of 25-800 ng/ml. The inter day and intra day assay accuracy and precision fulfilled the criteria specified by USFDA, Guidance for industry: bioanalytical method validation. Clozapine was found to be stable in human plasma after 6 h incubation at room temperature, 50 days storage at -27[degree sign] C and freeze thaw cycles, as well as after reconstitution with mobile phase after 24 h of storage in refrigerator. The validated method offers the advantage of using minimum injection volume [25micro l] and plasma sample volume [300micro l]. The extraction method is simple and single step with no back extraction step, thus, making this method applicable to determination of pharmacokinetic profiles and parameters


Subject(s)
Humans , Clozapine/blood , Clozapine/chemistry , Liquid-Liquid Extraction/methods , Reproducibility of Results , Sensitivity and Specificity , Antipsychotic Agents/blood , Calibration , Validation Studies as Topic